In this section you’ll find tips and solutions to common Frigidaire dehumidifier problems that owners face or may face in future times. These solutions are applicable to Frigidaire 30, 50 , and 70 pint dehumidifiers models.
Frigidaire Dehumidifier Clean Filter
Mi casa jika ma baby mp3 free download. When the “clean filter” lights stays on, then it’s time to do some cleaning top filter . This indicator is set to light on after 250 hours of operation, so you don’t have to worry.
How To Clean the filter on a Frigidaire Dehumidifier
To clean the filter, you remove it first. To remove the filter properly, pull the tabs using your hands in order not to scratch them and then take out the filter. Then run the filter under clean water then dry it. Don’t use an electric hair dryer to dry the air filter. Once the filter is dry, replace it on the rear of the dehumidifier and snap in place.
NB: It’s recommended that you clean the filter once every two weeks based on the dehumidifier being used in normal operating conditions.
Frigidaire Dehumidifier Not Working
If your dehumidifier is freezing up, then try these simple solutions first.
- Make sure that the plug is right in the wall outlet by pushing it firmly into wall outlet (the wall plug may disconnected).
- The fuse of your house may have blown or the circuit breaker may have tripped. Check if it’s the case, then replace the fuse by another one, or your house’s circuit breaker.
- The dehumidifier may not turn on if the water bucket is not installed properly.
- Also, the water tank may have reached its maximum. If this happens, the unit will automatically shut off. All you have to is to empty the water bucket and return it back to position.
- It may appear silly, but the dehumidifier may not be turned on, so turn it on.
Frigidaire Dehumidifier Not Collecting Water
To resolve this problem , follow these steps given by an expert.
- Make sure that the humidity extraction level is not very HIGH. Simply set it to 32-35%.
- Another area to check is the air filter as it could be clogged or dirty. Turn the unit OFF and unplug it. Remove the air filter by pulling the tabs. Inspect it and clean it if necessary. Leave it until it’s completely dry, then put it back. DO NOT turn the unit on without the filter.
- The unit may be close to a wall or an object which obstructs the air flow. Put it away from anything that could stop the air flow by maintain a minimum of 12 to 18″ of clear air space around your dehumidifier.
If none of the instructions above helped solve your problem, it may be a case of the compressor needs to be recharged with refrigerant gas. Also, if the your dehumidifier have been working for more than 5 years, the humidistat may have failed. This could also happen to a dehumidifier that has operated for less time. In this case, contact the manufacturer or consult other resources on our website.
If you have problems with your Frigidaire dehumidifier other than what we’ve covered here, please check your model’s manual in our Frigidaire Dehumidifiers Manuals page.
- Quick Links:
Related Manuals for Sunrise Forest Air 13-04595
Summary of Contents for Sunrise Forest Air 13-04595
- Page 1 o l l s ’ r ’ ©..
Page 2: Table Of Contents
TABLE OF CONTENTS USE ........3 SAFETY NOTES ......3 INSTALLATION Accessories and hardware .... 4 Tools needed ...... 4 Unpacking the air conditioner ...5 Electrical specifications ....5 Window requirements ....6 Preliminary instructions ....7 Window mounting ....8-9-10 UNIT OPERATION LED display control panel ...11 Cooling......Page 3: Use
Do not start or stop the unit by plugging in or pulling out the power cord. Always check the power cord for signs of damage before use. If the power cord is damaged, contact SUNRISE TRADEX Customer Service (see end of this manual). Do not install or use the unit in the following places: •..Page 4: Installation
INSTALLATION ACCESSORIES MAY DIFFER FROM ILLUSTRATIONS Before beginning installation, make sure to have close at hand all the tools you will need (listed below) and that all accessories and hardware parts provided with your air conditioner (as shown) are included. Top mounting rail and laterals (3 in total) Right Foam gasket..Page 5: Unpacking The Air Conditioner
Note : been detected. Do not use the air conditioner and/or attempt to reset the LCDI plug. Immediately contact SUNRISE TRADEX Customer Service (see end of this book). WARNING ! DO NOT PRESS the TEST button while the air conditioner is operating.Page 6: Window Requirements
INSTALLATION WINDOW REQUIREMENTS 1. These instructions and installation parts are for a standard double-hung window. It can be installed with our without the expandable panels. Make sure the opening is large enough for the unit size . Modify accordingly for other types of window. 2.Page 7: Preliminary Instructions
INSTALLATION INSTRUCTIONS Please read ALL instructions before installing. Two persons are recommend to install this product. If a new electrical outlet is required, have the outlet installed by a qualified electrician before installing unit. PRELIMINARY INSTRUCTIONS Do the following before starting to install unit. Window sash seal See illustrations below.Page 8: Window Mounting
WINDOW MOUNTING 1. Remove chassis 8. IMPORTANT : Mechanical damages 1. Pull down front panel and remove filter. could occur if the protections are not removed before starting the unit. Your (See fig.1). unit may come with internal packaging. 2. Lift front upwards and place to one side. This packaging must be removed prior 3.Page 9: Installation Instructions
INSTALLATION INSTRUCTIONS 3. Shift cabinet left or right as needed to line up cen- ter of cabinet on center line marked on stool. 4. Fasten cabinet to window stool with 2 screws into Air conditioner Plastic cabinet frame holes (you may wish to pre-drill pilot holes). Top view Locking ”I”..Page 10: Window Mounting 8
WINDOW MOUNTING 3. Install support brackets (with sill angle brackets 2. Attach right angle safety lock as shown. attached) to correct hole in bottom of cabinet as shown. 4. Tighten all 6 bolts securely. Safety lock 3/4” long hex-head screws 1/2”..Page 11: Led Display Control Panel
LED DISPLAY CONTROL PANEL To turn the air conditioner on or off. Temp Temp Energy Sleep Timer Timer Clean Check Saver Filter High Mode Timer Press this button to select the mode (in sequence) : On/Off Auto Cool Auto AUTO COOL DRY* Follow..Page 12: Cooling
UNIT OPERATION IMPORTANT NOTICE : Do not pierce the bottom of the air conditioner. Excess water is accumulated to cool down the temperature of the capacitor (outdoor unit). It is normal to hear the capacitor’s blade hit water accumulated in the bottom of the unit. Not respecting this notice will automatically void the warranty of the unit.Page 13: Energy Saver Mode
UNIT OPERATION ENERGY SAVER MODE This feature can be used when the air conditioner is COOLING. Based on set temperature, the fan cycles on and off with the compressor. This mode results in variations of room temperature and humidity. It is recommended to use this mode when the room is unoccupied. 1.Page 14: Remote Control
REMOTE CONTROL Your remote control may differ LED REMOTE DISPLAY from illustration. ON/OFF : Turns the unit on or off FAN : Sets fan speed to AUTO -LOW -MED -HIGH MODE : Sets operation mode to AUTO - COOL - DRY - HEAT - FAN TIMER : Sets the timer to an automatic TURN ON ENERGY SAVER : sets unit to..- Page 15 REMOTE CONTROL HOW TO OPERATE THE REMOTE CONTROL • This air conditioner has a built-in microcomputer memory that will save all set data ; when pressing ON/OFF to start the unit, operations set before the shut off will resume. ETTING THE REMOTE CLOCK Before operating the remote control, it is important to check and set the remote clock.
- Page 16 REMOTE CONTROL ETTING THE TEMPERATURE Press to set temperature - it will show on the remote Set Temp display When pressing and holding the keys together for 3 sec., display alternates between C and • Temperature cannot be set and does not show in FAN only mode. ETTING THE TIMER •..
Page 17: Air Vent And Air Direction Controls
AIR VENT AND AIR DIRECTION CONTROLS AIR VENT AND EXHAUST CONTROL. (ON CERTAIN MODELS ONLY) 1. For maximum continuous cooling, CLOSE the AIR VENT by completely pushing the tab in (Fig. A) ; only the air in the room is circulated. 2.Page 18: Maintenance
MAINTENANCE shock. • Always turn off and unplug the unit before cleaning to avoid electrical CLEANING THE FILTER The air filter is removable for easy cleaning. A clean filter helps to remove dust, lint and other particles from the air. A clean filter is also essential to maximize the cooling and operating efficiency of the air conditioner.Page 19: Troubleshooting
Refer to the unit rating plate and properly rated? modify power source accordingly. The unit starts and stops The internal evaporator and Call SUNRISE TRADEX frequently, or frequently outside condenser coils look dirty or Customer Service. obstructed by debris. blows fuses or trips the Make sure that there is no other circuit breaker.Page 20: Technical Specifications
If room temperature is not within the unit working range, it may not work properly. For the air conditioner technical specifications, data may vary ; please refer to the rating plate of the unit. CUSTOMER SERVICE Contact SUNRISE TRADEX Customer Service for : • Replacement parts • Technical support • Warranty claims..Page 21: Warranty
Note : The internal compressor is covered by a 5-YEAR limited warranty. During the warranty period, if this air conditioner fails under normal use, SUNRISE TRADEX CORP. will, at its option, either repair the unit or replace it, free of charge, within a reasonable period of time after the air conditioner is returned.